Light-duty Stainless Steel Vertical Multistage Centrifugal Pump

Product Application

  • Pressurization Water Supply: Water plant filtration & transmission, main pipe network pressurization, high-rise building water supply, fire water supply;
  • Water Treatment System: Ultrafiltration system, reverse osmosis system, distillation system, separator and swimming pool water treatment system;
  • Industrial Pressurization: High-pressure flushing system, cleaning system, process water system;
  • Industrial Liquid Transport: Cooling & air conditioning system, boiler feed water & condensate system, machine tool supporting;
  • Irrigation: Farmland irrigation, sprinkler irrigation, drip irrigation, etc.

Operating Conditions

Thin, clean liquid free of solid particles or fibers

Applicable for transporting mildly corrosive media

Medium Temperature: Normal temperature type 0℃~68℃, hot water type 0℃~120℃

Ambient Temperature: -15℃~+40℃

Max Ambient Pressure: 1.0 MPa

When the density or viscosity of transported medium is higher than water, a higher-power motor shall be considered.

BL/BLT series light-duty stainless steel vertical multi-stage centrifugal pump is a versatile product. It adopts optimized hydraulic models and advanced manufacturing processes. The wetted parts of the pump are stamped and welded from high-quality 304 stainless steel. The shaft seal adopts mechanical seal with hard alloy and fluororubber.
It can transport various media ranging from tap water to industrial liquids and is applicable for different temperature, flow rate and pressure ranges. The complete pump features compact structure, low noise, small footprint and remarkable energy-saving performance.

ModelPower(kW)Voltage(V)Inlet / Outlet DiameterQ(m³/h)1
0.28 L/S
1.2
0.33 L/S
1.6
0.44 L/S
2.0
0.56 L/S
2.4
0.67 L/S
2.8
0.78 L/S
3.2
0.89 L/S
3.5
0.97 L/S
BL(T)2-20.37220/380DN32H(m)181716151312108
BL(T)2-30.37220/380DN32H(m)2726242220181512
BL(T)2-40.55220/380DN32H(m)3635333026242016
BL(T)2-50.55220/380DN32H(m)4543403733302420
BL(T)2-60.75220/380DN32H(m)5352504540363024
BL(T)2-70.75220/380DN32H(m)6361575247412828
BL(T)2-91.1220/380DN32H(m)8078736761545137
BL(T)2-111.1220/380DN32H(m)9895898273645444
BL(T)2-131.5220/380DN32H(m)1161141069889786752
BL(T)2-151.5220/380DN32H(m)134130123112100907660
BL(T)2-182.2220/380DN32H(m)1611571481361211089176
BL(T)2-222.2220/380DN32H(m)19719218016514813011090
BL(T)2-263220/380DN32H(m)232228214198179158130110

ModelPower(kW)Voltage(V)Inlet / Outlet DiameterQ(m³/h)1.5
0.42 L/S
2.0
0.56 L/S
3.0
0.83 L/S
4.0
1.11 L/S
5.0
1.39 L/S
6.0
1.67 L/S
7.0
1.94 L/S
BL(T)4-20.37220/380DN32H(m)1918171513108
BL(T)4-30.55220/380DN32H(m)28272624201813
BL(T)4-40.75220/380DN32H(m)38363432272419
BL(T)4-51.1220/380DN32H(m)47454340343123
BL(T)4-61.1220/380DN32H(m)56545248403728
BL(T)4-71.5220/380DN32H(m)66635956484333
BL(T)4-81.5220/380DN32H(m)74726764555038
BL(T)4-102.2220/380DN32H(m)90878175656248
BL(T)4-122.2220/380DN32H(m)11410810495827558
BL(T)4-143220/380DN32H(m)1361261221121018968
BL(T)4-163220/380DN32H(m)15214414012911510178
BL(T)4-194380DN32H(m)18317116815313712293
BL(T)4-224380DN32H(m)211200192178160138108

ModelPower(kW)Voltage(V)Inlet / Outlet DiameterQ(m³/h)5
1.39 L/S
6
1.67 L/S
7
1.94 L/S
8
2.22 L/S
9
2.5 L/S
10
2.78 L/S
11
3.06 L/S
BL(T)8-20.75220/380DN50H(m)2019.51918171614
BL(T)8-31.1220/380DN50H(m)3029.528.527252413
BL(T)8-41.5220/380DN50H(m)4139.53836343219
BL(T)8-52.2220/380DN50H(m)52504845424026
BL(T)8-62.2220/380DN50H(m)62605754504632
BL(T)8-83220/380DN50H(m)83807773696539
BL(T)8-104380DN50H(m)1041009792878150
BL(T)8-114380DN50H(m)114110106101958655
BL(T)8-125.5380DN50H(m)1241201161041048778
BL(T)8-145.5380DN50H(m)145141136130122113102
BL(T)8-167.5380DN50H(m)166161156148139118106
BL(T)8-187.5380DN50H(m)187182175167157134120
BL(T)8-207.5380DN50H(m)208202195186175150135

ModelPower(kW)Voltage(V)Inlet / Outlet DiameterQ(m³/h)7
1.94 L/S
8
2.22 L/S
9
2.5 L/S
10
2.78 L/S
11
3.06 L/S
12
3.33 L/S
13
3.61 L/S
14
3.89 L/S
15
4.17 L/S
16
4.44 L/S
BL(T)12-21.5220/380DN50H(m)23.52322.522212018.5171514
BL(T)12-32.2220/380DN50H(m)35.535343331.53027262321
BL(T)12-43220/380DN50H(m)47464444424034303128
BL(T)12-53380DN50H(m)59.55856.55552.55043383935
BL(T)12-64380DN50H(m)71.5706666636052454542
BL(T)12-75.5380DN50H(m)83.58279.57773.57061535549
BL(T)12-85.5380DN50H(m)95.5948888848070616556
BL(T)12-95.5380DN50H(m)10810610310095.59079697464
BL(T)12-107.5380DN50H(m)120118114.5111106.510088778072
BL(T)12-127.5380DN50H(m)143.5141137133127120106929686
BL(T)12-1411380DN50H(m)168165160155148140132.5124112100
BL(T)12-1611380DN50H(m)192.5189183.5178170162142142128115
BL(T)12-1811380DN50H(m)217213207.5202192.5183151.5160145130

ModelPower(kW)Voltage(V)Inlet / Outlet DiameterQ(m³/h)8
2.22 L/S
10
2.77 L/S
12
3.33 L/S
14
3.89 L/S
16
4.44 L/S
18
5.00 L/S
20
5.56 L/S
22
6.11 L/S
BL(T)16-22.2220/380DN50H(m)2726252423211916
BL(T)16-33220/380DN50H(m)4140383734322925
BL(T)16-44380DN50H(m)5453504845423734
BL(T)16-55.5380DN50H(m)6867656258544943
BL(T)16-65.5380DN50H(m)8280787470655852
BL(T)16-77.5380DN50H(m)9695908682766861
BL(T)16-87.5380DN50H(m)1101081049995877870
BL(T)16-1011380DN50H(m)1381361311251181099785
BL(T)16-1211380DN50H(m)166162157151141132116105
BL(T)16-1415380DN50H(m)194190184175166152136122
BL(T)16-1615380DN50H(m)222217210200189174156140

ModelPower(kW)Voltage(V)Inlet / Outlet DiameterQ(m³/h)10
2.78 L/S
12
3.33 L/S
14
3.89 L/S
16
4.44 L/S
18
5.00 L/S
20
5.56 L/S
22
6.11 L/S
24
6.67 L/S
26
7.22 L/S
28
7.78 L/S
BL(T)20-22.2220/380DN50H(m)2726.52524232221201815
BL(T)20-34380DN50H(m)4039.53937353431292724
BL(T)20-45.5380DN50H(m)54535250494744413833
BL(T)20-55.5380DN50H(m)67666462605853504640
BL(T)20-67.5380DN50H(m)81797775727065615549
BL(T)20-77.5380DN50H(m)95939189868277716658
BL(T)20-811380DN50H(m)109105105102999489827667
BL(T)20-1011380DN50H(m)1361341281241181131111039381
BL(T)20-1215380DN50H(m)164162158150142138133124114102
BL(T)20-1415380DN50H(m)192189185174174166156145133119
BL(T)20-1718.5380DN50H(m)234230225212202192190177162145

ModelPower(kW)Voltage(V)Inlet / Outlet DiameterQ(m³/h)30
8.33 L/S
40
11.11 L/S
50
13.89 L/S
60
16.67 L/S
64
17.78 L/S
70
19.44 L/S
80
22.22 L/S
BL(T)64-2-27.5380DN100H(m)39363329262317
BL(T)64-2-111380DN100H(m)46444036333024
BL(T)64-211380DN100H(m)53514743403731
BL(T)64-3-215380DN100H(m)66625650464132
BL(T)64-3-115380DN100H(m)73696357534839
BL(T)64-318.5380DN100H(m)80767165595646
BL(T)64-4-218.5380DN100H(m)92878071676147
BL(T)64-4-122380DN100H(m)100947873736554
BL(T)64-422380DN100H(m)1071019485807461
BL(T)64-5-230380DN100H(m)12111410595888064
BL(T)64-5-130380DN100H(m)128121112102958771
BL(T)64-530380DN100H(m)1361291191091029478
BL(T)64-6-230380DN100H(m)15014213112011010181
BL(T)64-6-137380DN100H(m)15714913812511710888
BL(T)64-637380DN100H(m)16415614513212411595
BL(T)64-7-237380DN100H(m)17916915614113212199
BL(T)64-7-137380DN100H(m)186176163148139128106
BL(T)64-745380DN100H(m)193183170155146135112
BL(T)64-8-245380DN100H(m)207196182164154142116
BL(T)64-8-145380DN100H(m)214203189171161149123
BL(T)64-845380DN100H(m)221210196178168156130

ModelPower(kW)Voltage(V)Inlet / Outlet DiameterQ(m³/h)50
13.89 L/S
60
16.67 L/S
70
19.44 L/S
80
22.22 L/S
90
25 L/S
100
27.78 L/S
110
30.56 L/S
BL(T)90-2-211380DN100H(m)41393632282215
BL(T)90-215380DN100H(m)53504744403626
BL(T)90-3-218.5380DN100H(m)68656055494534
BL(T)90-322380DN100H(m)81777267555548
BL(T)90-4-230380DN100H(m)98938780726250
BL(T)90-430380DN100H(m)11010510092847666
BL(T)90-5-237380DN100H(m)126120113104939168
BL(T)90-537380DN100H(m)1391311241151069483
BL(T)90-6-245380DN100H(m)15514813912911710286
BL(T)90-645380DN100H(m)168160150141130117103

1. Product Features

  1. Structure It adopts vertical coaxial multistage construction, with the motor mounted on the top and multistage impellers connected in series vertically downward in the pump body. It features a compact footprint and requires minimal installation space. The pump shaft is directly coupled with the motor for simple installation. The wetted components (impellers, diffusers, pump chambers, inlet & outlet flanges) are made of stainless steel (normally 304, with 316L optional for certain working conditions). As a light-duty design, it comes with thinner casing walls, which differentiates it from heavy-duty industrial multistage pumps.
  2. Hydraulic Performance Pressurization is realized stage by stage through multistage impellers. It delivers low flow rate with high head. Its flow range is generally several cubic meters up to dozens of cubic meters per hour, while the head can reach tens to more than 300 meters. Stable continuous outlet pressure with low pressure pulsation during operation.
  • Precisely stamped hydraulic components with smooth surfaces for good hydraulic efficiency;
  • No rust contamination to conveyed fluid;
  • Suitable for clean water or thin low-corrosive liquids. Not applicable for media with high sand content or large solid particles due to weak wear resistance of the light-duty structure.
  1. Material Advantages Stainless steel wetted parts provide corrosion resistance and good hygienic performance. Lighter in weight compared with cast iron multistage pumps, easier for transportation and maintenance. However, its casing has lower pressure safety margin than heavy cast steel pumps with a lower maximum rated pressure, and long-time overpressure operation is prohibited.
  2. Operating Characteristics
  • Low noise and slight vibration;
  • Compatible with variable-frequency motors to achieve constant-pressure water supply and automatic pressure regulation;
  • Mechanical seal serves as the primary shaft seal with extremely low leakage under normal working conditions;
  • Applicable medium temperature range is usually 0~80℃ (hot water version available up to 120℃).
  1. Limitations (Key for Light-duty Type) The light-duty version cannot handle heavy loads, frequent pressure shocks or media with high solid content. Dry running and abrupt pressure changes will easily damage mechanical seals and stamped impellers.

2. Application Scenarios

  1. Building Water Supply (Most Common) Secondary pressurized water supply for high-rise residential buildings, office buildings and hotels; constant-pressure water supply sets in pump rooms equipped with VFD control cabinets to maintain stable pipeline water pressure.
  2. Water Treatment Industry Pressurization for reverse osmosis (RO) and ultrafiltration systems in pure water production; clean water delivery for water purification plants and bottled water production lines; transportation of softened water and deionized water.
  3. HVAC Systems Make-up water pumps for central air-conditioning cooling water, low-pressure boiler feed water, hot water pressurization and floor heating system pressurization.
  4. Light Industry Clean water transportation in food & beverage industry (304/316L hygienic type); purified water delivery for pharmaceutical industry; thin low-corrosive solutions in chemical industry (clean water-like, dilute weakly acidic/alkaline liquids, material verification required).
  5. Other Applications Fire sprinkler jockey pump (some models meet jockey pump parameters, cannot be used as main fire pump); high-pressure garden irrigation and pressurization for small cleaning equipment.

Not suitable for sewage, sediment-laden groundwater, high-concentration acid & alkali, high-viscosity media or heavy-duty high-temperature & high-pressure process conditions.

3. Routine Maintenance

3.1 On-site Inspection (During Operation)

  • Monitor outlet pressure and flow for stability and abnormal fluctuations;
  • Listen to pump and motor for abnormal friction or impact noise;
  • Check mechanical seal: only tiny dripping is permitted under normal status. Replace the seal immediately if leakage increases continuously;
  • Motor shell temperature generally shall not exceed 80℃; check operating current, which cannot exceed the rated value on nameplate;
  • Inspect pipelines and flanges for leakage, and check anchor bolts for looseness.

3.2 Periodic Servicing

  • Weekly: Check pressure gauges, valves and vibration dampers; clean dust and debris off pump exterior.
  • Monthly: Tighten anchor bolts; inspect motor bearing noise; check heat dissipation of control cabinet for VFD units.
  • Every 6 Months:
    • Inspect wear condition of mechanical seal;
    • Check impellers and diffusers for scale or blockage by impurities;
    • Measure motor insulation resistance;
    • Clean inlet strainer.
  • Annual Overhaul: Disassemble and inspect corrosion and wear of impellers and diffusers; replace aged mechanical seals and O-rings; check pump shaft wear and realign concentricity; remove scale inside pump chamber.

For long-term shutdown: drain all liquid inside pump chamber to prevent freeze cracking and internal corrosion; keep pump dry.

3.3 List of Wearing Parts

Mechanical seal, rubber O-rings, bearings, check valve assembly, inlet filter screen.

4. Operation Precautions

  1. Dry Running Strictly Forbidden The pump must be primed and all air vented before startup. Even short-time dry running will burn out mechanical seals, which is the most frequent failure of light-duty stainless steel multistage pumps. An inlet strainer must be installed to prevent solid particles from entering and scratching impellers and seals.
  2. Medium Requirements Conveyed liquid must be clean with negligible solid particles. The medium shall not cause severe corrosion to stainless steel. Grade 304 is only suitable for clean water and neutral mild media. 316L stainless steel shall be selected for high chloride water (seawater, high-chloride groundwater).
  3. Installation & Piping
  • Level the pump during installation. Inlet and outlet pipes shall be independently supported. Do not let pipeline weight bear on pump flanges, otherwise the thin stainless steel pump casing may crack.
  • Inlet piping must be airtight; air ingress leads to pump cavitation, unstable pressure and component damage.
  • Flexible connectors are recommended at inlet and outlet for vibration isolation. A check valve shall be fitted at pump outlet to protect stamped impellers from water hammer upon shutdown.
  1. Startup & Shutdown
  • Open inlet valve and close outlet valve before startup; slowly open outlet valve after power-on.
  • Frequent start-stop under full load is prohibited.
  • Stop pump immediately once cavitation occurs (loud noise and violent pressure fluctuation). Sustained cavitation will rapidly erode stainless steel impellers.
  1. Temperature & Pressure Do not exceed the medium temperature and maximum working pressure marked on nameplate. Long-term overpressure operation is prohibited. The stamped light-duty stainless steel casing has low pressure margin and is prone to deformation and leakage under overpressure.
  2. Electrical Safety Reliable earthing of motor; waterproof measures for humid pump rooms. For VFD operation, configure parameters per manufacturer requirements to avoid motor overheating caused by prolonged low-frequency running.
  3. Anti-freezing Protection When ambient temperature is below 0℃, drain all liquid inside pump after shutdown to prevent freeze burst.
Scroll to Top