đ Product Usage
Widely used for river cleaning, fountain landscaping, aquaculture, pumping well water, supplying water to highârise water towers in households, agricultural irrigation, horticulture, animal husbandry, and other industries.
âď¸
OIL IMMERSED ALL COPPER MOTOR
đ
HIGH HEAD AND LARGE FLOW
đĄď¸
OVERLOAD PROTECTION
âąď¸
LONG LIFESPAN
| S/N | Model | Rated flow (mÂł/h) | Rated head (m) | Rated power (kW) | Piping diameter (mm/in) |
|---|---|---|---|---|---|
| 1 | 50QY15â26â2.2 | 15 | 26 | 2.2 | 50(mm) / 2(in) |
| 2 | 65QY25â17â2.2 | 25 | 17 | 65(mm) / 2.5(in) | |
| 3 | 80QY40â12â2.2 | 40 | 12 | 80(mm) / 3(in) | |
| 4 | 100QY65â7â2.2 | 65 | 7 | 100(mm) / 4(in) | |
| 5 | 150QY100â4.5â2.2 | 100 | 4.5 | 150(mm) / 6(in) | |
| 6 | 50QY15â36â3 | 15 | 36 | 3 | 50(mm) / 2(in) |
| 7 | 65QY25â26â3 | 25 | 26 | 65(mm) / 2.5(in) | |
| 8 | 80QY40â16â3 | 40 | 16 | 80(mm) / 3(in) | |
| 9 | 100QY65â10â3 | 65 | 10 | 100(mm) / 4(in) | |
| 10 | 150QY100â6â3 | 100 | 6 | 150(mm) / 6(in) | |
| 11 | 65QY20â36/2â3 | 20 | 36 | 65(mm) / 2.5(in) | |
| 12 | 50QY10â54/3â3 | 10 | 54 | 50(mm) / 2(in) | |
| 13 | 50QY12.5â50â4 | 12.5 | 50 | 4 | 50(mm) / 2(in) |
| 14 | 65QY25â32â4 | 25 | 32 | 65(mm) / 2.5(in) | |
| 15 | 80QY40â21â4 | 40 | 21 | 80(mm) / 3(in) | |
| 16 | 100QY65â14â4 | 65 | 14 | 100(mm) / 4(in) | |
| 17 | 150QY160â6â4 | 160 | 6 | 150(mm) / 6(in) | |
| 18 | 50QY10â60/2â4 | 10 | 60 | 50(mm) / 2(in) | |
| 19 | 65QY25â40/2â4 | 25 | 40 | 65(mm) / 2.5(in) | |
| 20 | 50QY10â72/4â4 | 10 | 72 | 50(mm) / 2(in) | |
| 21 | 50QY10â85/3â5.5 | 10 | 85 | 5.5 | 50(mm) / 2(in) |
| 22 | 65QY20â62/3â5.5 | 20 | 62 | 65(mm) / 2.5(in) | |
| 23 | 65QY25â54/3â5.5 | 25 | 54 | ||
| 24 | 65QY25â50/2â5.5 | 25 | 50 | ||
| 25 | 80QY40â25â5.5 | 40 | 25 | 80(mm) / 3(in) | |
| 26 | 100QY65â18â5.5 | 65 | 18 | 100(mm) / 4(in) | |
| 27 | 150QY160â8â5.5 | 160 | 8 | 150(mm) / 6(in) | |
| 28 | 200QY250â5â5.5 | 250 | 5 | 200(mm) / 8(in) | |
| 29 | 50QY10â110/4â7.5 | 10 | 110 | 7.5 | 50(mm) / 2(in) |
| 30 | 65QY20â85/4â7.5 | 20 | 85 | 65(mm) / 2.5(in) | |
| 31 | 80QY40â38â7.5 | 40 | 38 | 80(mm) / 3(in) | |
| 32 | 100QY65â25â7.5 | 65 | 25 | 100(mm) / 4(in) | |
| 33 | 150QY160â9â7.5 | 160 | 9 | 150(mm) / 6(in) | |
| 34 | 200QY250â7â7.5 | 250 | 7 | 200(mm) / 8(in) | |
| 35 | 50QY10â165/6â11 | 10 | 165 | 11 | 50(mm) / 2(in) |
| 36 | 65QY20â130/6â11 | 20 | 130 | 65(mm) / 2.5(in) | |
| 37 | 65QY25â90/3â11 | 25 | 90 | ||
| 38 | 80QY40â58/2â11 | 40 | 58 | 80(mm) / 3(in) | |
| 39 | 100QY65â42/2â11 | 65 | 42 | 100(mm) / 4(in) | |
| 40 | 100QY100â25â11 | 100 | 25 | ||
| 41 | 150QY200â15â11 | 200 | 15 | 150(mm) / 6(in) | |
| 42 | 200QY250â10â11 | 250 | 10 | 200(mm) / 8(in) | |
| 43 | 50QY10â220/8â15 | 10 | 220 | 15 | 50(mm) / 2(in) |
| 44 | 65QY25â120/4â15 | 25 | 120 | 65(mm) / 2.5(in) | |
| 45 | 80QY40â84/3â15 | 40 | 84 | 80(mm) / 3(in) | |
| 46 | 100QY65â60/3â15 | 65 | 60 | 100(mm) / 4(in) | |
| 47 | 100QY65â50/2â15 | 65 | 50 | ||
| 48 | 100QY80â45â15 | 80 | 45 | ||
| 49 | 150QY160â25â15 | 160 | 25 | 150(mm) / 6(in) | |
| 50 | 200QY250â15â15 | 250 | 15 | 200(mm) / 8(in) | |
| 51 | 200QY400â9â15 | 400 | 9 |
Product Features
An oilâimmersed submersible electric pump is an integrated submersible unit whose motor cavity is filled with insulating cooling oil. The motor and pump share one shaft and operate fully submerged in water.
- Excellent cooling performance The motor chamber is filled with dedicated insulating cooling oil. Circulating oil dissipates heat from motor windings for stable thermal control. Compared with dryâtype submersible pumps, it is wellâsuited for longâduration continuous heavyâduty operation, with superior temperature rise control under highâhead conditions.
- Reliable sealing protection Mechanical seals isolate pumped water from the motor oil cavity. The insulating oil also lubricates sealing components. The unit tolerates water with a small amount of fine sediment and reduces seal wear.
- Compact structure & easy installation The pump and motor form one integrated assembly. No separate groundâlevel pump house, coupling or foundation frame is required. It can be lowered directly into wells, pools or water bodies, saving space and simplifying site work.
- Low operating noise Fully submerged underwater, the pump is insulated from vibration and noise by surrounding water, producing barelyâaudible noise above ground.
- Compatible with highâhead applications Multiâstage impeller design paired with an oilâfilled motor delivers high lift capacity, matching the QYâseries oilâimmersed submersible pumps in the parameter table for deepâwell longâdistance water lifting.
- Limitations
- If the mechanical seal fails, internal insulating oil may leak into water. It must NOT be used for potableâwater supply.
- Periodic oil inspection, topâup and replacement are required, meaning higher maintenance workload than dryâtype pumps.
- Not suitable for wastewater carrying large volumes of coarse sand or hard debris, as particles will rapidly abrade impellers and seals.
Application Scenarios
- Agricultural irrigation (primary use) Water extraction from shallow wells, largeâdiameter wells, rivers and reservoirs for farmland, orchard and nursery irrigation. Supports continuous highâvolume pumping for largeâscale farmland, ideal for QYâseries oilâimmersed submersible pumps.
- Water supply & drainage projects Temporary water supply for construction sites, circulation for landscape rivers and lakes, pond water replenishment and reservoir water intake.
- Industrial nonâpotable water transfer Industrial circulating water, tailing drainage with low fineâsediment content and nonâdrinking industrial water supply.
- Groundwater extraction Mediumâandâsmallâscale groundwater withdrawal from wells (for nonâpotable use only).
âNot applicable: domestic tapâwater / drinkingâwater supply (risk of oil contamination); heavy sewage and water loaded with substantial sand, gravel or fibrous waste.
Maintenance Guidelines
- Insulatingâoil inspection and replacement
- Inspect the oil cavity after the first 500 operating hours for new units. Afterwards, test insulating oil every 2000 operating hours or once per year.
- Drain all old oil and refill with special submersibleâpump insulating cooling oil if oil becomes emulsified by water ingress or turns black.
- Seal inspection Regularly measure motor insulation resistance. A sharp drop in insulation resistance usually indicates mechanicalâseal damage and water penetration into the oil chamber. Disassemble and replace mechanical seal parts.
- Impeller and pumpâchamber cleaning During seasonal shutdowns (offâpeak irrigation periods), lift the pump out of water. Clear sediment and water weeds from impellers and pump housing to prevent jamming.
- Powerâcable check Examine submersible power cable for cracks and outerâjacket damage. Cable joints must never sit submerged in water. Damaged cabling creates electricâshock hazards.
- Longâterm storage Do not leave the pump submerged in silty water for extended downtime. Rinse thoroughly and store upright in dry, wellâventilated conditions. Avoid horizontal placement to prevent uneven oil pooling.
Operating Precautions
- Medium requirements For clean water or water carrying limited fine sediment; sediment content in pumped water â¤0.1%. Liquid temperature â¤40âŻÂ°C. Do not pump strongly corrosive acidic or alkaline fluids.
- No dryârunning Start and run the pump only when it is fully under water. Exposed pump sections lose cooling and the motor will burn out quickly. Shut down promptly if water level falls.
- Powerâsupply protection Equip the system with earthâleakage protection, overload protection and phaseâloss protection. Threeâphase pumps burn out rapidly under phaseâloss conditions. Keep supplyâvoltage fluctuation within Âą10âŻ% of rated voltage.
- Startup constraints Frequent onâoff cycling damages mechanical seals from hydraulic shock. Allow at least 5âminute intervals between consecutive starts.
- Installation requirements Maintain minimum 30âŻcm clearance between pump bottom and well/pool bottom to avoid drawing in bottom silt. Ensure suction inlet is not fully blocked by mud or aquatic plants.
- Electrical safety Reliably ground the complete unit. Cut off power completely before any underwater installation or inspection to prevent electric shock.
- Oilâleak response Shut down the pump immediately if an oil film appears on the water surface. Inspect for broken seals. Continued operation risks water pollution and permanent motor failureă